Jotul GF300 BV User Manual

Browse online or download User Manual for Fireplaces Jotul GF300 BV. Jotul GF300 BV User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
Installation
and
Operation
Instructions
GF 300 BV Allagash
Gas Stove
IF THE INFORMATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN-
ITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER, SERVICE
AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL SWITCHES.
• DO NOT USE THE PHONE IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A
NEIGHBOR’S PHONE.
• FOLLOW YOUR GAS SUPPLIER’S INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER,
CALL THE FIRE DEPARTMENT.
WARNING:
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS-FITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
A CARBON MONOXIDE (CO) DETECTOR SHALL
BE INSTALLED IN THE SAME ROOM AS THE
APPLIANCE.
AVERTISSEMENT:
ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUC-
TIONS DANS CETTE NOTICE POUR REDUIRE AU
MINIMUM LE RISQUE D’INCENDIE OU POUR EVITER
TOUT DOMMAGE MATERIEL, TOUTE BLESSURE OU
MORTALIT’E.
NE PAS ENTREPOSER NI UTILISER D’ESSENCE NI
OU LIQUIDES INFLAMMABLES DANS LE VOISINAGE
DE CET APPAREIL OU DE TOUT AUTRE APPAREIL.
L’INSTALLATION LE SERVICE DOIVENT ETRE
EXECUTES PAR UN INSTALLATEUR QUALIFIE,
AGENCE DE SERVICE OU LE FOURNISSEUR DE
GAZ.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.
• NE PAS TENTER D’ALLUMER L’APPAREIL
• NE TOUCHEZ A AUCUM NTERRUPTEUR.
• NE PAS VOUS SERVIR DES TELEPHONES SE
TROUVANT DANS LE BATIMENT OU VOUS VOUS
TROUVEZ.
• APPELEZ IMMEDIATEMENT VOTRE FOURNISSEUR
DE GAZ CHEZ UN VOISIN. SUIVEZ LES INSTRUC-
TIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE
FOURNISSEUR DE GAZ, APPELEZ LE SERVICE DES
INCENDIES.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Gas Stove

1InstallationandOperationInstructionsGF 300 BV AllagashGas StoveIF THE INFORMATION IN THESE INSTRUCTIONSARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-SION

Page 2 - Welcome to Jøtul

10Approved B-Vent ConfigurationsNOTE:Installation ataltitude greaterthan 2000’requiresminimum 12 ft.vertical rise fromDraft Hood.NOTE:Installation ata

Page 3 - Gas Heater

11Fuel Conversion Procedure1. Turn off gas supply to stove.2. Remove the stove Top Plate.3. Disengage the two Glass Frame Latches at the top ofthe fir

Page 4 - Specifications

127. Lift out the Burner Plate: NOTE: There are no screwssecuring the Burner to the floor of the firebox. Pull theAir Shutter forward and lift the bur

Page 5 - General Information

13Gas Supply ConnectionThe gas supply line connection is made to the left side ofthe front-mounted valve. The gas supply line should be3/8" npt w

Page 6 - Safety Information

14Gas PressureCorrect gas pressure is essential for efficient and safeoperation of the GF 300 BV gas stove. It is importantthat the correct pressure

Page 7 - Depth = 1

15Log Set InstallationBrick Kit Note: Install the optional Antique Brick Kit155370 before installing the logset. See page 22 andthe instructions pro

Page 8 - Vent Requirements

16CloseOpenOptional Wall Thermostat orRemote ControlUse only a 750 millivolt DC two-wire circuit thermostatwith this appliance. The thermostat should

Page 9 - Prefabricated Manufactured

17System Check1. PURGING THE GAS LINE: When lighting the appli-ance for the first time, it will take a few moments toclear the gas line of air. Once

Page 10 - Figure 7

18OperationFamiliarize yourself with the controls of the GF 300 BV.Make sure that anyone else using the appliance is alsofamiliar with the controls an

Page 11 - Fuel Conversion Procedure

19Glass CareClean the glass only when necessary. Wipe the surfacewith a clean, dampened, soft cloth. Follow with a dry,soft towel. Take care not to sc

Page 12

2Welcome to Jøtul...Congratulations on the purchase of your newJøtul GF 300 BV Allagash gas stove.We at Jøtul are glad you’ve made the decision towarm

Page 13 - Gas Supply Connection

20Optional Blower # 155620Figure 33. Blower Kit Components THIS BLOWER MUST BEELECTRICALLY GROUNDED INACCORDANCE WITH LOCAL CODESOR, IN THE ABSEN

Page 14 - Gas Pressure

21Blower OperationThe optional variable-speed blower will enhance heatcirculation around the firebox and out into the room.The blower is controlled by

Page 15

22Figure 38. Brick Kit ContentsOptional Antique Brick Kit# 155648Figure 39.Disengage thecompression latchesto remove the glassframe.Figure 41. Inst

Page 16 - Remote Control

23High Altitude AdjustmentInstallations burning natural gas and located at altitudesfrom 2000 - 4500 ft. (610 M - 1370 M), require compen-sation for t

Page 17

24ONLY USE REPLACEMENTPARTS PROVIDED BY ANAUTHORIZED JØTUL DEALER. Figure 44.212019181716151413121111098222233242526 27 28313233363738394041 42 43 44

Page 18 - BLOWERBURNER

258. Side Clip ... 1284019. Bolt, M6 x 12 mm (Side to Base) ...

Page 19 - Maintenance

26MODEL NAME: ________________________SERIAL NUMBER: ______________________DATE OF PURCHASE: ___________________PURCHASED FROM: ____________________NA

Page 20 - Optional Blower # 155620

273. Access the lower controls.4. Depress gas control knob slightly and turn clock-wise to “OFF”. Do not force.FOR YOUR SAFETY, READ BEF

Page 21 - RHEOSTAT

28Jøtul ASP.O. Box 1411N-1602 FredrikstadNorwayJøtul North America55 Hutcherson DriveGorham, Maine 04038-2634October 2005 137945-CThis appliance mus

Page 22 - # 155648

3Table of ContentsService Tools ... 4Specifications ... 4General In

Page 23 - High Altitude Adjustment

4GF 300 BV AllagashSpecificationsThe Jøtul GF300 BV Allagash is a atmospherically-vented gas fireplace heater designed only forvertical venting direct

Page 24 - Illustrated Parts Breakdown

5General Information THIS HEATER MUST BE INSTALLED AND MAINTAINEDBY A QUALIFIED SERVICE AGENCY. The installation and repair of this appliance must b

Page 25 - Accessories

6LocationIn selecting a location for the stove, consider thefollowing points:1) Heat distribution2) Vent termination requirements3) Gas supply line

Page 26

7Stove and Vent ClearanceRequirementsMinimum Clearances from the Stoveto Combustibles See figs. 2-3.Rear: 2” (51 mm) - measured from Draft HoodCeili

Page 27 - LIGHTING INSTRUCTIONS

8Vent RequirementsThe GF 300 BV Allagash is specifically designed tooperate using 4” Type B vent pipe components or a ListedFlexible gas liner.• All v

Page 28 - 137945-C

9• When 6” diameter decorative pipe is installed tocover the venting any Listed Flexible Gas liner mustbe connected directly to the stove’s draft hood

Comments to this Manuals